<strong>The</strong> Lubrication System<br />
Duplex Oil Filter<br />
In many instances, compressed air systems operate on a continuous basis. Since it is frequently inconvenient<br />
to completely shut down compressor operation to perform a simple maintenance task, Cooper<br />
<strong>Turbo</strong>compressor offers the Duplex Oil Filter option. <strong>The</strong> duplex oil filter eliminates the necessity for<br />
compressor shutdown during filter maintenance. (Refer to Section Five, Maintenance, for full instructions<br />
regarding this procedure.) <strong>The</strong> Duplex Oil Filter option is shown in Figure B—5.<br />
Figure B—5 <strong>The</strong> Duplex Oil Filter<br />
Oil Filter Differential Pressure Monitoring<br />
With this optional feature, a second pressure transducer is installed before the oil filter. (<strong>The</strong> system’s<br />
standard pressure transducer is located between the filter and the gearbox.) In such instances, the<br />
Vantage Control System is programmed to calculate the differential pressure across the oil filter and to<br />
provide Alarm and Trip functions. <strong>The</strong> Oil Filter Differential Pressure Monitoring option is particularly<br />
useful when included as part of a predictive maintenance program. Figure B—6 shows the Oil Filter<br />
Differential Pressure Monitoring option.<br />
Oil from Cooler<br />
Oil Filter<br />
Figure B—6 Oil Filter Differential Pressure Monitoring Option<br />
Oil to Gearbox<br />
Low Oil Level Indicator<br />
With the installation of the Low Oil Level Indicator option (a switch located in the main oil reservoir)<br />
the Vantage Control System will report any oil level in the reservoir that is below a pre-defined level.<br />
<strong>The</strong> control system then indicates an Alarm condition to alert the operator of the problem.<br />
B—9