5.5.6 <strong>Design</strong> <strong>of</strong> longitudinal web stiffeners<br />

<strong>The</strong> critical buckling load <strong>of</strong> a longitudinally loaded orthogonally stiffened web<br />

has been derived in Section 5.5.4 as<br />

Pcro ¼ 2p2 E<br />

B<br />

Isx Isy<br />

a b<br />

with the notations as in that section.<br />

For a particular ratio <strong>of</strong> the moments <strong>of</strong> inertia <strong>of</strong> the transverse and<br />

longitudinal stiffeners I sy and I sx, see Figure 5.26, P cro will be equal to the sum<br />

<strong>of</strong> the Euler buckling loads <strong>of</strong> the longitudinal stiffeners, i.e. when<br />

or<br />

2p 2 E<br />

B<br />

Isx Isy<br />

a b<br />

Isy ¼ 1 IsxbB<br />

4<br />

2<br />

a3 1=2<br />

¼ p 2 E Isx<br />

a 2<br />

With this value <strong>of</strong> Isy, the half-wave-length L will be<br />

B<br />

Isx a<br />

1=4<br />

b Isy<br />

B<br />

b<br />

¼ ffiffiffi p<br />

2a<br />

1<br />

1=2<br />

B<br />

b<br />

2<br />

B<br />

B b<br />

If I sy is greater than the above value, the sum <strong>of</strong> the Euler buckling loads will<br />

be less than Pcro; there is also the possibility that there may not be a transverse<br />

stiffener within the half-wave-length L, thus invalidating the evaluation <strong>of</strong> P cro<br />

as above. Hence in this situation the longitudinal stiffeners should be designed<br />

as struts with effective length equal to a.<br />

If I sy is less than the above value, the orthotropic critical buckling load P cro<br />

will be less than the sum <strong>of</strong> the Euler buckling loads <strong>of</strong> the longitudinal<br />

stiffeners. Hence the longitudinal stiffeners should be designed as struts with<br />

effective length leff greater than a and given by<br />

wherefrom<br />

p 2 EIsx<br />

l 2 eff<br />

B<br />

b<br />

leff ¼ B<br />

2<br />

Rolled Beam and Plate Girder <strong>Design</strong> 147<br />

1 ¼ 2p2 E<br />

B<br />

B<br />

b<br />

1<br />

Isx Isy<br />

a b<br />

1=2 abIsx<br />

<strong>The</strong> axial loading on a longitudinal stiffener should include not only the<br />

longitudinal stresses in the girder web, but should also allow for the destabilising<br />

effects <strong>of</strong> shear stresses and any transverse stresses in the web. Thus the<br />

applied longitudinal stress should be taken as<br />

s1 þ 2:5ksðt þ s2Þ<br />

Isy<br />

1<br />

1=2<br />

1=2<br />

1=4