longitudinal compression <strong>of</strong> the longitudinal stiffeners, as per Hencky–Mises’<br />
yield criterion. Being localised, these transverse stresses are also not likely to<br />
cause any destabilising effects.<br />
6.5 Orthotropic buckling <strong>of</strong> stiffened flange<br />
Orthotropic buckling <strong>of</strong> the stiffened flange between the webs <strong>of</strong> the main<br />
girders provides a restraining effect on the buckling <strong>of</strong> the longitudinal flange<br />
stiffeners as individual parallel struts. This orthotropic behaviour produces two<br />
separate effects on the stress conditions <strong>of</strong> individual longitudinal stiffeners:<br />
(1) Under the same magnitude <strong>of</strong> the applied longitudinal compressive load<br />
across the flange width, the magnification <strong>of</strong> the initial deflection <strong>of</strong> the<br />
strut in an orthotropic panel is less than that <strong>of</strong> an isolated strut.<br />
(2) As the whole flange width between girder webs buckles, the applied longitudinal<br />
compression varies across this width, with higher stresses along the<br />
edges (i.e. near the girder webs) and lower stresses along the central strips.<br />
<strong>The</strong> word ‘orthotropic’ is an abbreviation <strong>of</strong> the feature ‘orthogonally anisotropic’;<br />
in such a plate the lack <strong>of</strong> isotropy is due to different flexural rigidities<br />
in the orthogonal directions, even though the plate is <strong>of</strong> uniform thickness. <strong>The</strong><br />
elastic critical buckling stress <strong>of</strong> an orthotropic plate under longitudinal compression,<br />
i.e. the value <strong>of</strong> the applied stress at which an ideally flat residualstress-free<br />
orthotropic panel becomes unstable and suddenly deflects from its<br />
initially flat plane, is given by<br />
where<br />
Stiffened Compression Flanges <strong>of</strong> Box and Plate Girders 165<br />
scro ¼ p2<br />
tb 2<br />
Dx<br />
f 2 þ Dyf 2 þ 2H ð6:4Þ<br />
t ¼ thickness <strong>of</strong> the orthotropic plate<br />
b ¼ width <strong>of</strong> the orthotropic plate<br />
a ¼ length <strong>of</strong> the orthotropic plate<br />
Dx; Dy ¼ are the flexural rigidities in the x and y directions, respectively<br />
H ¼ torsional rigidity<br />
f ¼ aspect ratio <strong>of</strong> the buckled panel, i.e. a/(mb)<br />
m ¼ number <strong>of</strong> half-waves in the longitudinal dimension a.<br />
For a minimum value <strong>of</strong> s cro, ds cro/df ¼ 0, i.e. f 4 ¼ D x/D y, leading to<br />
scro ¼ 2p2<br />
tb 2<br />
pffiffiffiffiffiffiffiffiffiffi<br />
DxDy þ H ð6:5Þ<br />
and the half-wavelength <strong>of</strong> buckling l in the longitudinal direction is given by<br />
l ¼ b Dx<br />
Dy<br />
1=4