For interaction <strong>of</strong> various stress components the following ratios are calculated:<br />

mc ¼ s1g mg f3<br />

syK1<br />

mb ¼ sbg mg f3<br />

syKb<br />

mq ¼ tg mg f3<br />

syKq<br />

2<br />

¼<br />

2<br />

¼<br />

¼<br />

107 1:05 1:1<br />

355 0:675<br />

43 1:05 1:1<br />

355 1:205<br />

60 1:05 1:1<br />

355 0:966<br />

mc þ mb þ 3mq ¼ 0:652 < 1:00<br />

¼ 0:516<br />

2<br />

¼ 0:013<br />

2<br />

¼ 0:041<br />

Hence the panel is safe for buckling.<br />

(2) Middle panel: this panel is subjected to 4.8 N/mm 2 tensile, 68.8 N/mm 2<br />

bending and 60 N/mm 2 shear stresses. Being an internal panel, it is deemed to<br />

be restrained.<br />

Buckling stress coefficients are obtained from Reference [2] for<br />

rffiffiffiffiffiffiffi<br />

b sy<br />

¼ 80, and f ¼<br />

t 355<br />

150<br />

¼ 1:875<br />

80<br />

as follows:<br />

K1 ¼ 48<br />

Kb ¼ 1:15; interpolating between f ¼ 1 and 2<br />

Kq ¼ 0:939<br />

4:8 1:1 1:05<br />

mc ¼<br />

355 0:48<br />

2<br />

68:8 1:1 1:05<br />

mb ¼<br />

355 1:15<br />

mq ¼<br />

60 1:1 1:05<br />

355 0:939<br />

mc þ mb þ 3mq