Hybrid Damping for Direct Dynamic Analysis<br />

Hybrid damping is now available in RADIOSS.<br />

This is a means of applying modal damping in a direct frequency response or direct transient response<br />

analysis.<br />

This is recommended mainly for residual models, where a large part of the structure is represented by<br />

external super elements. This is because of the computational expense of this feature.<br />

It is activated via the HYBDAMP subcase information entry, which in turn references a HYBDAMP Bulk<br />

Data entry.<br />

Additionally, the DMIGMOD entry has been expanded to allow hybrid damping to be defined for<br />

external super elements only (HYBDAMP will apply damping to both residual structure and external<br />

super elements).<br />

Frequency Dependent Spring Property<br />

A frequency dependent spring property is now available in RADIOSS.<br />

Similar to the existing PBUSHT frequency dependent bushing property definition, a PELAST frequency<br />

dependent spring property definition has been added. It may be referenced by spring elements<br />

(CELAS1, CELAS3).<br />

Speed of the Modal Frequency Response Analysis Solution<br />

The speed of the modal frequency response analysis solution has been dramatically increased for<br />

problems that have a large number of modes and structural damping and/or viscous damping.<br />

Results for a SET of GRID Can be Requested from a CMS Super Element<br />

During a residual run, the results from a SET of ASET and interior GRID can be requested. In the past<br />

only NODMIG or DMIGALL were allowed on the OUTPUT command. Now DMIGSET is supported.<br />

The Fluid-Structure Coupling Matrix Can Now be Written to the .pch File.<br />

The fluid-structure coupling (Area) matrix can now be output to the .pch file in DMGI format using the<br />

PARAM,AGGPCH,YES command.<br />

SPCD Data Created for CMS Super Elements for Each Mode During Eigenvalue Analysis<br />

A .spcd file is created during an eigenvalue analysis of a model that contains CMS Super Elements.<br />

This file contains SPCD data for each ASET GRID and SPOINT for each mode. This SPCD data can be<br />

used in a following run to recover the internal results for a specific mode.<br />

PFMODE and PFPANEL Can Write Results to the .h3d, .pch, or Both Files<br />

The results from PFMODE and PFPANEL can be written out to the .h3d file, the .pch file, or both files.<br />

PFMODE Output Can Now be Determined by Displacement, Velocity, or Acceleration<br />

The option RTYPE has been added to the PFMODE data in order to specify DISP, VELO, or ACCE to<br />