• FRACTURE CRITERION (group; part of DEBOND card)<br />

• CONTROLS, TYPE=VCCT LINEAR SCALING (group)<br />

Explicit interface:<br />

• COHESIVE BEHAVIOR (group; part of SURFACE INTERACTION card)<br />

• FRACTURE CRITERION (same as the above)<br />

Improved Displacement System Support<br />

The system card image shows now, to which node set it is assigned.<br />

You can now unassign a node set, by either removing the TRANSFORM flag from the card image or by<br />

assigning it back to the global system. This can be done from the System panel by selecting the global<br />

system in the lower left side of the GUI.<br />

Ply and Laminate Support<br />

Both entities are now enabled for the Abaqus interface. More details are provided in the generic<br />

HyperMesh section of these release notes and in the plies and laminate documentation of the<br />

HyperMesh User Guide.<br />

3D ply visualization including ply orientation is now supported for shells and continuum shells.<br />

Laminate definitions can now be realized into Abaqus properties. Pre-condition is that a composite<br />

property has to be assigned to the elements. Both, shell and shell general section definitions have<br />

been enhanced to interact with ply and laminate entities.<br />

Composites Panel<br />

The normals subpanel in the Composites panel has been enhanced to support continuum shells<br />

(currently only available in Abaqus interface).<br />

• In addition to regular shell elements ‘display normals’ can now show the default stacking<br />

direction of continuum shells based on their numbering scheme. This button does not consider<br />

the STACK DIRECTION setting on the element property.<br />

• ‘Display stack direction’ accounts for the STACK DIRECTION parameter setting of the element<br />

property for review. Supported are the settings in all three isoparametric directions (1, 2, 3) but<br />

also the system reference).<br />

• Review options are the same as with regular shells: vector and color display.<br />

• Two options to adjust the default stacking direction for continuum shells are available now:<br />

Selected elements can either be adjusted by selecting a reference element or a user can specify<br />

the base face by two diagonal or three base nodes.<br />

Systems Panel<br />

The assign subpanel of the Systems panel has a new option called attach nodes as set for the Abaqus<br />

interface. Now a user can simultaneously assign nodes to a displacement system and simultaneously<br />

create a node set.<br />

Resolved Issues<br />

• HM comments for *ORIENTATION have not been honored upon import when the system definition<br />

is based on nodes or is defined without the origin.