04.07.2013 Views

Complete Material Standards Manual - Gainesville Regional Utilities

Complete Material Standards Manual - Gainesville Regional Utilities

Complete Material Standards Manual - Gainesville Regional Utilities

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Cone, Manhole Section, Eccentric<br />

<strong>Material</strong> Item Approved for Use In:<br />

Water System:<br />

Wastewater System:<br />

Reclaimed Water System:<br />

Approved Manufacturers:<br />

Manufacturer's Name: Model/Series #:<br />

Del Zotto Products<br />

Hanson Pipe & Products, Inc<br />

Standard Precast, Inc<br />

<strong>Material</strong> Description:<br />

Eccentric cone manhole section with bitumastic<br />

coating constructed precast concrete with tongue<br />

& groove joint coated with ram-nek primer.<br />

Application:<br />

Gravity wastewater systems.<br />

See Appendix B for Installation Instructions<br />

Pictures are for Illustrative Purposes Only<br />

GRU Stock Information:<br />

CONE, ECCENTRIC MH<br />

Stock Number Stock Description<br />

000467855 48" x 2'-0"<br />

000456802 48" x 3'-0"<br />

'For GRU use only: An X indicates item is stockless<br />

National <strong>Standards</strong>:<br />

ASTM C443 - Precast Reinforced Concrete<br />

ASTM C478/AASHTO M199 - Precast Concrete<br />

See Appendix A for Full Description of <strong>Standards</strong><br />

Water, Wastewater and Reclaimed Water<br />

<strong>Material</strong> <strong>Standards</strong><br />

C-40.00<br />

6/10/2009