18.08.2013 Views

SPIRE Design Description - Research Services

SPIRE Design Description - Research Services

SPIRE Design Description - Research Services

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Draft <strong>SPIRE</strong> <strong>Design</strong> <strong>Description</strong> Document<br />

Subsystem<br />

Name<br />

Beam<br />

Steering<br />

Mechanism<br />

(BSM)<br />

FTS<br />

Mechanism<br />

(SMECm)<br />

FTS encoder<br />

amplifier<br />

(SMECp)<br />

Shutter<br />

Mechanism<br />

Photometer<br />

Calibration<br />

Source<br />

Spectrometer<br />

Calibration<br />

Source<br />

(SCAL)<br />

RF Filter<br />

Modules<br />

Photometer<br />

JFET Box<br />

Spectrometer<br />

JFET Box<br />

Detector<br />

Read-out &<br />

Control Unit<br />

(DRCU)<br />

FPU Control<br />

Unit (FCU)<br />

<strong>Description</strong> Unit Redundancy<br />

This mechanism allows the photometer and<br />

spectrometer fields of view to be stepped or chopped<br />

across the sky.<br />

The FTS moving mirrors drive mechanism and<br />

position measurement system. SMECm designates the<br />

mechanism and position encoder<br />

SMECp the cold pre-amplifier for the position encoder<br />

detectors.<br />

A shutter is required in the instrument for ground test<br />

to allow the detectors to see the correct radiation<br />

environment.<br />

25<br />

HSFPU No redundancy in the<br />

structure, mirror or<br />

flexure pivots.<br />

Redundancy in<br />

instrumentation,<br />

actuation and<br />

harnessing.<br />

HSFPU No redundancy in the<br />

structure, mirror or<br />

flexure pivots.<br />

Redundancy in<br />

instrumentation,<br />

actuation and<br />

harnessing.<br />

HSFPU Fully redundant<br />

HSFPU No redundancy as not a<br />

flight item.<br />

Calibration source for photometer HSFPU No redundancy on light<br />

guide and reference<br />

source. Full<br />

redundancy on<br />

electronics and<br />

harnesses.<br />

Calibration source for the spectrometer HSFPU Redundancy on<br />

reference source heater<br />

and thermometer. Full<br />

redundancy on<br />

electronics, heater and<br />

Each sub-system harness into the cold FPU must have<br />

an electrical RF filter to prevent EMI problems with<br />

the bolometers. These will be mounted in standard RF<br />

filter modules on the wall of the FPU box.<br />

JFET pre-amplifiers for photometer NTD germanium<br />

bolometers.<br />

JFET pre-amplifiers for spectrometer NTD germanium<br />

bolometers.<br />

Detector amplifier and digitisation chain and<br />

instrument control electronics. Conceptually this is a<br />

single unit however for accomodation reasons it will<br />

be split into two phyiscal units<br />

Contains the electronics for the power conversion and<br />

distribution to the DRCU; for the control and read-out<br />

of the thermometers; cooler; calibration sources and<br />

the cold mechanisms<br />

harnesses.<br />

HSFPU Fully redundant<br />

HSFTBp No redundancy. Failure<br />

of single JFET<br />

amplifier is a soft<br />

failure mechanism<br />

HSFTBs No redundancy. Loss<br />

of a single JFET<br />

amplifier is a soft<br />

failure mechanism<br />

HSDRC See below<br />

HSFCU Full redundancy