Power distribution components<br />

2+2 Raceway<br />

four circuit, eight-wire raceway for panels<br />

power rails<br />

Morrison<br />

description type w d h pattern no. list price<br />

Power rail for panel base 24w 6 2 2 MR3-E24 $150.<br />

30w 12 2 2 MR3-E30NS 166.<br />

36w 18 2 2 MR3-E36NS 180.<br />

42w 24 2 2 MR3-E42NS 193.<br />

48w 30 2 2 MR3-E48NS 200.<br />

60w 42 2 2 MR3-E60NS 213.<br />

Multiple outlet power rails 48w 30 2 2 MR3-E48-4 285.<br />

60w 42 2 2 MR3-E60-4 300.<br />

Panel Planning<br />

Power rail for vertical raceway 2 2 30 MR3-EVR 425.<br />

Data Shield 1 pair MR3-DATSHD 29.<br />

Order Code<br />

Example: MR3-E48-4<br />

MR3 Morrison<br />

E Eight wire2+2<br />

48 For 48 panel<br />

4 Multiple outlets<br />

Specification Information<br />

Morrison 2 +2 Raceway is a<br />

four-circuit, eight-wire modular<br />

power distribution system, for use in<br />

Morrison panels and Network desk<br />

supports.2+2Raceway<br />

components distribute two 20-amp<br />

convenience circuits (A and B), with<br />

neutral and ground, and two<br />

protected 20-amp circuits (X and Y)<br />

with separate neutral and ground.<br />

89<br />

Application Notes<br />

Power rails are the primary power<br />

distribution component of the<br />

Morrison2+2Raceway. Each rail<br />

provides outlet mounting positions<br />

on both sides, and receptacles for<br />

two branching power connectors at<br />

each end. Center supports permit<br />

lay-in cabling from either side of the<br />

raceway.<br />

Rail for 24 wide panel accepts one<br />

duplex outlet or power infeed<br />

centered on each side. Rails for 30<br />

and wider panels accept two outlets<br />

(or one outlet and one infeed) each<br />

side, 12 from either end of the<br />

panel. Multiple outlet power rails<br />

accept up to four duplex outlets<br />

each side.<br />

Power rail for vertical raceway<br />

accepts up to four duplex outlets<br />

each side, two above and two below<br />

standard worksurface height. Power<br />

rail for vertical raceway includes<br />

power connector from adjacent<br />

powered panel base.<br />

If separation of cabling and<br />

electrical wires is required, a data<br />

shield can be attached below the<br />

power rail. Data shields are field<br />

installed.