Power distribution components<br />
2+2 Raceway<br />
four circuit, eight-wire raceway for panels<br />
outlets and infeeds<br />
Morrison<br />
description type pattern no. list price<br />
Duplex outlets, black Circuit A MR3-DA $39.<br />
Circuit B MR3-DB 39.<br />
Circuit X MR3-DX 39.<br />
Circuit Y MR3-DY 39.<br />
Duplex outlets, orange Circuit X MR3-DXO 46.<br />
Circuit Y MR3-DYO 46.<br />
Duplex outlets, black with orange triangle Circuit X MR3-DXT 46.<br />
Circuit Y MR3-DYT 46.<br />
Panel Planning<br />
Power infeeds - Panel base<br />
(reversible)<br />
panel base MR3-ERPI 261.<br />
SF MR3-EPSF 261.<br />
Power infeeds - Ceiling external power pole MR3-EPIC 300.<br />
vertical raceway MR3-EPVR 261.<br />
Power infeeds - hardwire NYC - one direction MR3-EPNY1 220.<br />
NYC - two directions MR3-EPNY2 332.<br />
Order Code<br />
Specification Information<br />
Application Notes<br />
Example: MR3-EPVR<br />
MR3 Morrison raceway<br />
E Eight wire2+2<br />
P Power infeed<br />
VR For vertical raceway<br />
Morrison 2 +2 Raceway is a<br />
four-circuit, eight-wire modular<br />
power distribution system, for use in<br />
Morrison panels and Network desk<br />
supports.2+2Raceway<br />
components distribute two 20-amp<br />
convenience circuits (A and B), with<br />
neutral and ground, and two<br />
protected 20-amp circuits (X and Y)<br />
with separate neutral and ground.<br />
Duplex outlets are preconfigured to<br />
access one of the four circuits, A, B,<br />
X, Y, and snap into any standard<br />
outlet location (12 from either end<br />
of panel). Duplexes on circuits X<br />
and Y may be specified with orange<br />
face or black face with orange<br />
triangle to signify protected circuits<br />
for electronic equipment.<br />
Power infeeds connect building<br />
power supply to a cluster of<br />
interconnected power rails. Panel<br />
base infeed snaps into any outlet<br />
position in rail, 12 from either side<br />
of panel, and includes 6 foot<br />
liquid-tight conduit and pigtail for<br />
connection to floor or wall electrical<br />
box. MR3-ERPI Panel Base Infeed<br />
rotates to provide either a left- or<br />
right-hand power entry.<br />
Ceiling infeeds include<br />
12-6pigtail for connection into<br />
panel base through Morrison<br />
vertical raceway and ceiling infeed<br />
panel, or through standard power<br />
pole (supplied by others) adjacent to<br />
Morrison panel with power rail.<br />
Hardwire infeed, used in all New<br />
York City installations, includes<br />
junction box that mounts within<br />
non-powered panel base (any width<br />
24 or greater). Electrical contractor<br />
supplies conduit from building<br />
power supply to panel, punches<br />
infeed hole in raceway cover, and<br />
trims power connectors to length.<br />
MR3-EPNY2 includes two power<br />
connectors to power panels on both<br />
sides of infeed panel; MR3-EPNY1<br />
includes only one power connector.<br />
Template is included to modify<br />
standard N-type raceway cover<br />
(without outlet openings).<br />
Power infeed for Panel base for San<br />
Francisco installations have a<br />
liquid-tight sleeve over a metallic<br />
flexible conduit.<br />