Beltway Electrical<br />
Specifications<br />
Dividends Horizon<br />
Beltway Power Jumpers<br />
Beltway power jumpers connect between<br />
power modules in nonadjacent panels.<br />
Beltway power jumpers take the place<br />
<br />
duplexes to provide pass-through power.<br />
Three versions are available:<br />
<br />
<br />
<br />
Single panel beltway jumpers carry power from<br />
a panel with a beltway power module through a<br />
single non-electrified panel to an adjacent panel<br />
with a beltway power module when a post is<br />
not involved in straight line configurations only.<br />
Single beltway panel jumpers with post<br />
carry power from a panel with a power<br />
module through a single non-electrified<br />
panel and post connector to an adjacent<br />
panel with a beltway power module in<br />
straight through post configurations only.<br />
Multiple beltway panel jumpers carry power<br />
from a panel with a power module through<br />
multiple panels with or without a post to<br />
the next available beltway power module<br />
in straight line configurations only.<br />
Specify one beltway power jumper per panel<br />
that matches the width of the panel for passthrough<br />
electrical where duplexes are not<br />
<br />
90° Beltway Power Jumper<br />
A 90° beltway power jumper connects<br />
adjacent beltway power modules at<br />
a 90° ‘‘L’’ panel connection.<br />
The following illustrations outline the<br />
<br />
beltway applications with a post.<br />
Note: A 90° beltway power jumper can<br />
only be used with adjacent panels in a<br />
‘‘X’’, ‘‘T’’ or ‘‘L’’ conditions. The 90° jumper<br />
cannot be used to span multiple panels.<br />
To specify correct jumper length, determine the<br />
largest panel width between the two adjacent<br />
corner panels in which jumper is to be installed.<br />
Vertical Power Jumpers<br />
To carry power from the base raceway<br />
to the beltway located in the same panel<br />
<br />
power jumpers function as an extension<br />
of the base raceway power system.<br />
Attachment is from any unused outlet position<br />
in the base raceway to the end terminal<br />
block connection in the beltway power<br />
module. The vertical power jumper cable is<br />
concealed in the cavity of the panel frame.<br />
Power can also be carried to a beltway run<br />
from the base raceway of an adjacent panel<br />
with a power module. This is accomplished<br />
by using a panel power jumper.<br />
Specify one vertical power jumper per<br />
beltway electrical run not to exceed<br />
the electrical systems capacity. See<br />
the technical specifications for the<br />
electrical system being utilized.<br />
Note: Length of power jumper allows for<br />
connections with or without post conditions.<br />
Power Infeeds<br />
A ceiling infeed may also be used to<br />
bring power directly to the beltway power<br />
module without having to go directly<br />
to a base raceway power module.<br />
Duplex Receptacles<br />
Duplex receptacles provide access to<br />
power along the beltway. Duplexes<br />
used in the beltway are the same as the<br />
duplexes used in the base raceway.<br />
Two duplex receptacles can be installed<br />
per panel side in beltway raceways 30" and<br />
wider. 24"W panels will accept beltway power<br />
jumpers for pass-through power only.<br />
Receptacles insert into terminal blocks<br />
in outlet positions at either end of power<br />
modules and attach with a single screw.<br />
Beltway Power Jumper<br />
Beltway Power Jumper Configurations<br />
Beltway Vertical<br />
Power Jumper<br />
(Adjacent Panel)<br />
Beltway Post Connections<br />
2-way “L”<br />
Beltway Electrical Components<br />
Power Connector, no post<br />
Electrical/Data<br />
Components<br />
Power Jumper<br />
Power Jumper,<br />
with post<br />
4-way “X”<br />
Legend<br />
Beltway Vertical<br />
Power Jumper<br />
3-way “T”<br />
Power Module<br />
Power Jumper<br />
Power Jumper,<br />
with post<br />
193