Cable Management<br />

Specifications<br />

Dividends Horizon<br />

Base Raceway Cable Tray<br />

Optional steel cable trays are available for<br />

installations requiring the use of data and<br />

communications cables within the base raceway.<br />

The cable tray mounts between the panel feet.<br />

Cable trays are field-installed and<br />

accessible from either side of the base<br />

raceway. A single sided base raceway<br />

cable tray should be specified when<br />

attaching to a tile-to-floor panel base.<br />

Note: Cables should not be installed in<br />

base raceways without cable trays.<br />

Beltway Cable Tray<br />

An optional cable tray is available for data and<br />

communications cables within the beltway.<br />

Beltway cable trays should be used when wires<br />

are being routed horizontally from panel-topanel<br />

at the beltway. The cable tray mounts<br />

into slots located on the vertical panel frame.<br />

Cable trays are 1 1 / 4" high, 1 5 / 16" deep<br />

and are field-installed. Construction is<br />

<br />

Note: Beltway cable trays can be installed<br />

in monolithic panels to provide additional<br />

mid span insert support when required.<br />

Worksurface Cable Management Basket<br />

Constructed of black finished steel wire, the<br />

worksurface cable management basket mounts<br />

to the underside of worksurfaces to provide<br />

management of excess cords and cables. Once<br />

installed, the cable management basket slides<br />

forward to a position abutting the panel face<br />

to allow the passage of cords and cables.<br />

Specify by width available between<br />

worksurface supports. Black finish.<br />

Worksurface cable management baskets are<br />

1 1 / 2" high, 3 1 / 2" deep and 19 1 / 2" to 41 1 / 2" wide.<br />

Vertical Wire Pathway Grommet<br />

An optional plastic grommet that snaps into the<br />

vertical wire pathway on the horizontal panel<br />

frame to separate cables from the panel frame.<br />

Located in center of topway and base raceway.<br />

Topway Cable Grommet<br />

The primary location for cable management<br />

for Dividends Horizon is in the topway. In order<br />

to utilize the topway channel effectively, the<br />

outside knockouts must be removed by using<br />

pliers. When the knockouts are removed the<br />

cables can be easily managed in the channel.<br />

If required, a topway knockout grommet may<br />

be installed inside of the topway channel. Four<br />

grommets would be required per panel topway<br />

Worksurface Cable Management Clip<br />

An optional cable management clip. 3 / 4" x<br />

1<br />

/ 2" (internal dimension) plastic clip manages<br />

cables on the underside of worksurfaces.<br />

Data Shield<br />

If separation of cabling and electrical wires is<br />

required within the base raceway, a data shield<br />

can be attached below a base raceway power<br />

module at either end. Data shields are fieldinstalled.<br />

The data shield should be used with<br />

base raceway panels or tile to floor panels only.<br />

Vertical Wire Pathway<br />

Worksurface Cable<br />

Management Clip<br />

Base Raceway<br />

Cable Tray<br />

Beltway Cable Tray<br />

Topway Cable<br />

Grommet<br />

Data Shield<br />

Worksurface Cable<br />

Management Basket<br />