Chapter 1: <strong>7401</strong>-2xxx/3xxx Product Overview 1-21<br />

Cash Drawer I/O Port Bit Definition:<br />

Bit # Description Bit = 1 Bit = 0<br />

7 Solenoid B Control Turns off solenoid<br />

output<br />

6 Solenoid A Control Turns off solenoid<br />

output<br />

Activates solenoid<br />

output<br />

Activates solenoid<br />

output<br />

5 Reserved Reserved Reserved<br />

4 Reserved Reserved Reserved<br />

3 Solenoid B Status Solenoid B output<br />

active<br />

2 Solenoid A Status Solenoid A output<br />

active<br />

Solenoid B output<br />

inactive<br />

Solenoid A output<br />

inactive<br />

1 Reserved Reserved Reserved<br />

0 Cash Drawer(s) Status Drawer(s) open Drawer(s) closed<br />

Note: Bits 2 and 3 are set to ʹ1ʹ by each device reset.<br />

The cash drawer interface can be diagnosed remotely. For security<br />

reasons, the cash drawer diagnostics mode must first be activated by<br />

pressing an external momentary switch (SW2). The intention is for<br />

authorized personnel to be present when the cash drawer diagnostic<br />

tests take place.<br />

There is only one cash drawer status signal; therefore, bit 0 is the status<br />

of either cash drawer or both cash drawers.