<strong>MC52i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

<br />

8.9 <strong>AT</strong>^MONP<br />

8.9 <strong>AT</strong>^MONP Monitor neighbor cells<br />

The <strong>AT</strong>^MONP supplies information of up to six neighbor cells. There are two ways to retrieve the information:<br />

once on request by using the execute command or automatically every seconds by using the write<br />

command. To stop the periodic presentation type "<strong>AT</strong>" or "at".<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^MONP=?<br />

Response(s)<br />

^MONP:(list of supported s)<br />

OK<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>^MONP<br />

Response(s)<br />

See: Section 8.9.1, <strong>AT</strong>^MONP responses<br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^MONP=<br />

Response(s)<br />

See: Section 8.9.1, <strong>AT</strong>^MONP responses<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last<br />

- + + + + + - - -<br />

Parameter Description<br />

(num)<br />

Display period in seconds<br />

1...254<br />

Notes<br />

• Due to the fact that not all necessary information of the neighbor cells can be decoded during a connection,<br />

there are several constraints to be considered:<br />

- Only neighbor cells that have already been visible in IDLE mode will be further updated, as long as they<br />

are still included in the list.<br />

- Though new neighbor cells can be added to the list (e.g. due to handover), their C1 and C2 parameters<br />

cannot be displayed until the connection is released. In this case "-" will be presented for C1 and C2.<br />

• To some extent, the cell monitoring command <strong>AT</strong>^SMONC covers the same parameters. The receiving level,<br />

for example, can be queried with both commands. Yet the resulting values may be slightly different, even<br />

though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the<br />

cell information is permanently updated.<br />

• For compatibility with earlier products and to support legacy applications, any input character may be used to<br />

stop the output in certain cases (depending on the settings of <strong>AT</strong>+IPR and <strong>AT</strong>+CMUX).<br />

<strong>MC52i</strong>_<strong>AT</strong>C_V01.201 Page 184 of 551 4/16/10<br />