18.3 <strong>AT</strong>^SBC<br />

Notes<br />

• If multiplex mode (<strong>AT</strong>+CMUX) is active, any virtual channel can be used for entering the read or write command.<br />

The undervoltage URC will be issued simultaneously on all three channels.<br />

• The URC "^SYSSTART CHARGE ONLY MODE" is indicated automatically when the module enters this mode<br />

(except when autobauding is active). Unlike the undervoltage URC, it cannot be disabled or enabled by the<br />

TE.<br />

18.3.1 Responses returned by read command<br />

Responses returned by the <strong>AT</strong>^SBC read command vary with the operating mode of the <strong>MC52i</strong>:<br />

• Normal mode: <strong>MC52i</strong> is switched on by Ignition pin and running in SLEEP, IDLE, TALK or D<strong>AT</strong>A mode.<br />

Charger is not connected. The <strong>AT</strong>^SBC read command indicates the battery capacity and the current consumption<br />

of the <strong>MC52i</strong> module and the application (if value of application was specified before as ).<br />

• Normal mode + charging: Allows charging while <strong>MC52i</strong> is switched on by Ignition pin and running in SLEEP,<br />

IDLE, TALK or D<strong>AT</strong>A mode. The <strong>AT</strong>^SBC read command returns only charger status and current consumption<br />

of the <strong>MC52i</strong> module and the application. Percentage of battery capacity is not available.<br />

• CHARGE ONLY mode: Allows charging while <strong>MC52i</strong> is detached from GSM network. When started, the mode<br />

is indicated by the URC "^SYSSTART CHARGE ONLY MODE". The <strong>AT</strong>^SBC read command returns only the<br />

charger status and current consumption of the <strong>MC52i</strong> module and the application. Percentage of battery<br />

capacity is not available. In CHARGE ONLY mode a limited number of <strong>AT</strong> commands is accessible (see<br />

Appendix). There are several ways to activate the CHARGE ONLY mode:<br />

- from POWER DOWN mode: Connect charger while the <strong>MC52i</strong> was powered down with <strong>AT</strong>^SMSO<br />

- from Normal mode: Connect charger, then enter <strong>AT</strong>^SMSO.<br />

• Alarm mode: The battery can be charged while the <strong>MC52i</strong> stays in Alarm mode, but the <strong>AT</strong>^SBC read command<br />

returns only charger status and current consumption of the <strong>MC52i</strong> module and the application. Percentage<br />

of battery capacity is not available.<br />

<strong>MC52i</strong>_<strong>AT</strong>C_V01.201 Page 505 of 551 4/16/10<br />