30.06.2014 Views

MC52i AT Command Set

MC52i AT Command Set

MC52i AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MC52i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

<br />

2.8 <strong>AT</strong>+CFUN<br />

2.8 <strong>AT</strong>+CFUN Functionality Level<br />

<strong>AT</strong>+CFUN serves to control the functionality level of the ME. It can be used to reset the ME, to choose one of the<br />

SLEEP modes or to return to full functionality.<br />

Intended for power saving, SLEEP mode reduces the functionality of the ME to a minimum and thus minimizes<br />

the current consumption. Further information, particularly power supply ratings during the various operating<br />

modes and the timing of hardware signals in SLEEP mode can be found in the "<strong>MC52i</strong> Hardware Interface<br />

Description, Version 01.201".<br />

SLEEP mode falls in two categories:<br />

• NON-CYCLIC SLEEP mode =0<br />

• CYCLIC SLEEP modes, selectable as = 5, 6, 7, 8 or 9.<br />

NON-CYCLIC SLEEP mode permanently blocks the serial interface. The CYCLIC SLEEP mode, however, is a<br />

dynamic process which alternatingly enables and disables the serial interface. The major benefit of all CYCLIC<br />

SLEEP modes is that the serial interface remains accessible and that, in intermittent wake-up periods, characters<br />

can be sent or received without terminating the selected mode. The best choice is using = 7, 8 or 9, since<br />

in these modes <strong>MC52i</strong> automatically resumes power saving, after you have sent or received a short message or<br />

made a call. =5 or 6 do not offer this feature to the same extent and are only supported for compatibility<br />

with earlier releases. In all CYCLIC SLEEP modes, you can enter =1 to permanently wake up <strong>MC52i</strong> and<br />

take it back to full functionality. Please refer to Section 2.8.1, Wake up the ME from SLEEP mode for a summary<br />

of all SLEEP modes and the different ways of waking up the module.<br />

For CYCLIC SLEEP mode (= 5, 6, 7, 8 or 9) both the ME and the application must be configured to use<br />

hardware flow control. This is necessary since the CTS signal is set/reset every time when the ME listens to a<br />

paging message from the base station. This is the way how the module indicates to the application when the<br />

UART is active. For detailed information on the timing of the CTS signal refer to [2]. The default setting of hardware<br />

flow control is <strong>AT</strong>\Q0 which must be altered to <strong>AT</strong>\Q3. For use after restart you are advised to add it to the<br />

user profile saved with <strong>AT</strong>&W.<br />

If both interfaces ASC0 and ASC1 are connected, hardware flow control must be set in either application. See<br />

notes below for further detail.<br />

The <strong>AT</strong>+CFUN test command returns the values of the supported parameters.<br />

The <strong>AT</strong>+CFUN read command returns the current functionality value.<br />

The <strong>AT</strong>+CFUN write command can be used to reset the ME, to choose one of the SLEEP modes or to return to<br />

full functionality.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+CFUN=?<br />

Response(s)<br />

+CFUN: (list of supported s) , (list of supported s)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>+CFUN?<br />

Response(s)<br />

+CFUN: <br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>+CFUN=[[, ]]<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

<strong>MC52i</strong>_<strong>AT</strong>C_V01.201 Page 39 of 551 4/16/10<br />