30.06.2014 Views

MC52i AT Command Set

MC52i AT Command Set

MC52i AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MC52i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

<br />

18.2 <strong>AT</strong>+CALA<br />

18.2 <strong>AT</strong>+CALA <strong>Set</strong> alarm time<br />

The <strong>AT</strong>+CALA write command can be used to set an alarm time in the ME When the alarm time is reached and<br />

the alarm is executed the ME returns an Unsolicited Result Code (URC) and the alarm time is reset to "00/01/<br />

01,00:00:00".<br />

The alarm can adopt two functions, depending on whether or not you switch the ME off after setting the alarm:<br />

• Reminder message: You can use the alarm function to generate reminder messages. For this purpose, set<br />

the alarm as described below and do not switch off or power down the ME. When executed the message<br />

comes as an Unsolicited Result Code which reads "+CALA".<br />

• Alarm mode (only applicable to <strong>MC52i</strong> Module, not permitted for <strong>MC52i</strong> Terminal): You can use the alarm<br />

function to restart the ME when powered down. For this purpose, set the alarm as described below. Then<br />

power down the ME by entering the <strong>AT</strong>^SMSO command. When the alarm time is reached, the ME will wake<br />

up to Alarm mode. To prevent the ME from unintentionally logging into the GSM network, Alarm mode provides<br />

restricted operation. Upon wake-up, the ME indicates an Unsolicited Result Code which reads:<br />

"+CALA". A limited number of <strong>AT</strong> commands is available during Alarm mode, for details see Section 20.4,<br />

Availability of <strong>AT</strong> <strong>Command</strong>s Depending on Operating Mode of ME. The ME remains deregistered<br />

from the GSM network.<br />

If you want the ME to return to full operation (normal operating mode) it is necessary to restart the ME by<br />

driving the ignition line (IGT pin of application interface) to ground.<br />

If your ME is battery powered note that the battery can be charged while the ME stays in Alarm mode. For<br />

details please refer to [2].<br />

The <strong>AT</strong>+CALA test command returns the supported array index values , the supported alarm types <br />

and the maximum length of the text to be output.<br />

The <strong>AT</strong>+CALA read command returns the current alarm settings in the ME.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+CALA=?<br />

Response(s)<br />

+CALA: (list of supporteds), (list of supporteds), (list of supporteds)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Read <strong>Command</strong><br />

<strong>AT</strong>+CALA?<br />

Response(s)<br />

+CALA: [, [, [, ]]]<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Write <strong>Command</strong><br />

<strong>AT</strong>+CALA=[, [, [, ]]]<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last Reference(s)<br />

- + + + + + + + - GSM 07.07<br />

<strong>MC52i</strong>_<strong>AT</strong>C_V01.201 Page 500 of 551 4/16/10<br />

Confidential / Released

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!