4.2 Panel mounted version<br />
These units have a bezel 'd' on the front section of the enclosure 'e'. Special clamps 'f' allow<br />
easy fixing to panels up to 23 mm (0.9") thick.<br />
d<br />
e<br />
f<br />
Fig. 10<br />
f<br />
1. Ensure that there is adequate clearance behind the panel where the <strong>M800</strong> flow computer<br />
is to be mounted (140 mm [5.5"] minimum). Room should be left for wiring to connect<br />
into the rear of the unit.<br />
2. Cut an aperture in the panel as shown in Figure 11.<br />
<br />
<br />
151 +1 /0 mm<br />
(6")<br />
R5 (0.2") maximum<br />
<br />
<br />
236 +1 /0 mm<br />
(9.3")<br />
<br />
Fig. 11 Cut-out detail for panel mounted version<br />
14<br />
IM-P333-25 MI Issue 2