6.3 Commissioning mode<br />

The commissioning mode is used to set the <strong>M800</strong> to the pipeline flow, temperature and<br />

pressure sensors, set and test the outputs and change the pass code.<br />

All data entry is performed via a menu and sub menu configuration with the key pad buttons<br />

used for navigation, i.e. to go deeper into the menu the right hand key is pressed, to<br />

scroll up and down the menu the up and down keys are pressed and to exit<br />

from a sub-menu the left key is pressed. The display will step down a line each time<br />

a sub-menu is entered and display the previous menu title.<br />

For example:-<br />

Commissioning mode<br />

• Basic Data<br />

Key<br />

press<br />

Commissioning mode<br />

• Basic Data<br />

• Units<br />

Key<br />

press<br />

Commissioning mode<br />

• Basic Data<br />

• Units<br />

Met<br />

Key<br />

press<br />

Commissioning mode<br />

• Basic Data<br />

• Units<br />

Imp<br />

Data to be edited is always displayed on the bottom right of the screen. Pressing the OK key<br />

will enter new data. By pressing the up and down keys, the display will scroll through the<br />

available data and the previously entered selection will flash. After a period of ten minutes<br />

without any keys being pressed, the <strong>M800</strong> will automatically return to the run mode.<br />

You can enter the commissioning mode from the run mode<br />

(apart from the error and alarm screen) by pressing and holding<br />

down the 'OK' key for 5 seconds. The display then shows: Enter pass<br />

8888<br />

The flashing leading digit indicates the position of the cursor. The default, or factory set pass<br />

code is 8888 (this can be changed from within the commissioning mode). The pass code can<br />

be entered by using the up and down keys to increment or decrement the flashing value<br />

and the left and right keys to move the cursor.<br />

Pressing 'OK' will enter the pass code. If an incorrect pass code<br />

is used, the display automatically returns to the run mode.<br />

After the correct pass code is entered the display shows:<br />

Commissioning mode<br />

• Basic Data<br />

To exit the commissioning mode at any stage, pressing and holding the left key will<br />

return the <strong>M800</strong> to the run mode.<br />

Pressing the up and down buttons scrolls through the various first level menus.<br />

Pressing the right arrow button enters a particular sub-menu.<br />

IM-P333-25 MI Issue 2 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!