HISTORICAL PERSPECTIVE 2<br />

Two other enclosure scenarios have design and flood insurance implications. Designers should be cautious<br />

when an owner asks for either type of enclosure, and should consult with the community and a knowledgeable<br />

flood insurance agent:<br />

<br />

Enclosures that do not extend all the way to the ground (sometimes called “above-grade,”<br />

“hanging,” or “elevated” enclosures). These enclosures have a floor system that is not in contact<br />

with the ground, but that may be connected to the building foundation or supported on the primary<br />

pile system or short posts (Figure 2-23). Having the floor of the enclosure above grade means frequent<br />

flooding passes underneath, which may reduce the frequency and severity of damage. These enclosures<br />

were not contemplated when flood insurance premium rate tables were prepared, and thus can result in<br />

significantly higher flood insurance premiums. As of early 2011, the NFIP was working to address this<br />

type of construction, but until such time as it is resolved, owners will pay a substantial premium penalty<br />

for this type of enclosure.<br />

<br />

Two-story enclosures. In flood hazard areas with very high BFEs, some owners have constructed twostory,<br />

solid walls to enclose areas below elevated buildings, typically with a floor system approximately<br />

midway between the ground and the elevated building (Figure 2-24). These enclosures present unique<br />

problems. In Zone A, the walls at both levels of the enclosure must have flood openings; there must be<br />

some means to relieve water pressure against the floor system between the upper and lower enclosures;<br />

and special ingress and egress code requirements may apply. These enclosures may also result in<br />

substantially higher flood insurance premiums.<br />

Figure 2-23.<br />

Above-grade enclosure<br />

(Perry, FL)<br />

COASTAL CONSTRUCTION MANUAL<br />

2-29