the original dish was used to calculate the original broth biomass concentration<br />

(milligrams per liter <strong>of</strong> broth). Another 100 mL <strong>of</strong> the same broth (broth a) was<br />

subjected to a number <strong>of</strong> dilutions <strong>and</strong> analyzed for optical density. These dilutions<br />

provided a range <strong>of</strong> known concentrations with measured optical densities <strong>and</strong> were<br />

used to plot the dry-weight calibration curve for Pseudomonas putida. Samples with<br />

optical densities exceeding the range <strong>of</strong> the calibration curve were diluted until their<br />

optical densities fell within the calibrated range.<br />

3.3.2 Analyses <strong>of</strong> Organic Chemicals<br />

Prior to measuring the substrate concentrations, samples from bioremediation<br />

experiments were centrifuged at 2500 rpm for 5 min to let the bacteria settle to the<br />

bottom <strong>of</strong> the tube, then the supernatant was mixed with an equal volume <strong>of</strong> an aqueous<br />

solution <strong>of</strong> 1-butanol, the internal st<strong>and</strong>ard, to measure substrate concentrations in the<br />

liquid samples.<br />

<strong>Ethanol</strong>, toluene <strong>and</strong> benzyl alcohol concentrations in the liquid were analyzed<br />

using a GC (HP 5890) equipped with a Flame Ionizing Detector (FID) <strong>and</strong> capillary<br />

column (PTE TM 5 Fused Silica Capillary Column, 30 m, 0.25 mm ID, Supelco, Inc., PA,<br />

USA). The temperatures <strong>of</strong> the injector <strong>and</strong> detector were 210 ºC <strong>and</strong> 250 ºC,<br />

respectively. The oven temperature was ramped from 45 ºC to 150 ºC at the rate <strong>of</strong><br />

25 o C/min. 1-Butanol was used as the internal st<strong>and</strong>ard for all liquid sample analyses.<br />

<strong>Ethanol</strong>, toluene <strong>and</strong> benzyl alcohol st<strong>and</strong>ards were prepared as aqueous solutions for<br />

the calibration <strong>of</strong> the GC analyses. The calibration curves are shown in the Appendix B<br />

(See Figures B-4 to B-6).<br />

36