Assembly<br />

4.2 Hollow shaft version CDH-75<br />

4.2.1 Requirements<br />

●<br />

Danger of death, serious physical injury and/or damage to property<br />

due to deactivation of safety functions, caused by an unstable shaft<br />

drive!<br />

‣ The system manufacturer must implement suitable design measures,<br />

so that the drive of the measuring system is ensured at all times<br />

through the shaft and mounting of the measuring system (fault<br />

exclusion). The specifications of DIN EN 61800-5-2:2008 "Adjustable<br />

speed electrical power drive systems, Safety requirements - Functional,<br />

Table D.16 – Motion and position sensors" must be observed.<br />

‣ In general, the requirements and acceptance conditions for the<br />

complete system must be taken into account for mounting.<br />

As the installation situation is application-dependent, the following<br />

notes are not exhaustive.<br />

‣ The measuring system must be installed on a grease-free shaft.<br />

‣ Axial slipping of the measuring system on the drive shaft must be<br />

prevented by the fixing of the clamping ring, see Figure 4.<br />

‣ Further measures may be required to prevent axial slipping of the<br />

measuring system.<br />

‣ The clamping of the measuring system must not be axially loaded.<br />

‣ The screw of the clamping ring must be tightened with 3 Nm using a<br />

torque wrench.<br />

‣ The screw must be secured against unintentional loosening.<br />

‣ Radial slipping of the measuring system on the drive shaft must be<br />

prevented by means of form closure, using a parallel key / groove<br />

combination; the measuring system must be fixed on the side of the<br />

drive using a dowel pin, see Figure 5.<br />

‣ In case of applications with low ambient temperatures, increased values<br />

for the start-up torque result. This fact is to be considered when the<br />

assembling and wave drive is performed.<br />

© <strong>TR</strong>-<strong>Electronic</strong> GmbH 2010, All Rights Reserved Printed in the Federal Republic of Germany<br />

Page 128 of 207 <strong>TR</strong> - ECE - BA - DGB - 0079 - 03 05/25/2011