Safety Program Creation - Configuration Example<br />
‣ The Runtime Group is defined with the function FC1. In the field Max. cycle<br />
time of the F-runtime in ms: enter the value 400 and confirm with OK.<br />
Also confirm the next window Edit F-Runtime Groups with OK.<br />
The programming and modifications are now complete.<br />
8.5 Generating the safety program<br />
To generate the safety program, in SIMATIC Manager, Options --> Edit safety<br />
program menu, open the Safety Program dialog. The safety program is compiled<br />
and generated with the Compile switch.<br />
If compilation is successful 0 warnings are displayed, and the windows can then be<br />
closed.<br />
Printed in the Federal Republic of Germany<br />
© <strong>TR</strong>-<strong>Electronic</strong> GmbH 2010, All Rights Reserved<br />
05/25/2011 <strong>TR</strong> - ECE - BA - DGB - 0079 - 03 Page 181 of 207