University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

55. Clear Space at Doors - Door to Courtyard from Room #111 on the<br />

1st Floor of <strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong>-55-1 (originally 1446-400)<br />