Report #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong><br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

140-Seating, Tables and<br />

Work Surfaces: Room<br />

#205 on the 2nd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>. [Fume<br />

hood. Relocate the<br />

flammable box.]<br />

27" high, 30" wide and 19" deep knee clearance<br />

provided.<br />

Replace the fume hood with an<br />

accessible fume hood<br />

workstation.Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

3 $18,277.25 Until such time<br />

as accessible<br />

furniture /<br />

stations are<br />

available in this<br />

room staff shall<br />

be informed of<br />

the immediate<br />

availability of<br />

accessible<br />

furniture /<br />

stations that<br />

may be placed<br />

in the room to<br />

meet the needs<br />

of people with<br />

disabilities.<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

141-Protruding Objects:<br />

Room #205 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Fume hood.]<br />

Objects projecting from walls (i.e. telephones,<br />

etc.) have 4" maximum projection into walks,<br />

halls, corridors, passageways or aisles if lower<br />

edge of object is above 27" and below 80".<br />

Install cane detectable barrier<br />

below object.<br />

1 $245.01<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

142-Protruding Objects:<br />

Room #205 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Emergency eyewash.]<br />

Objects projecting from walls (i.e. telephones,<br />

etc.) have 4" maximum projection into walks,<br />

halls, corridors, passageways or aisles if lower<br />

edge of object is above 27" and below 80".<br />

Install cane detectable barrier<br />

below object.<br />

1 $122.51<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

143-Aisles: Room #205<br />

on the 2nd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

36" minimum width of aisles. Requires<br />

engineering/architectural<br />

evaluation.<br />

2 $7,115.62<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

144-Doors: Rooms #205<br />

and #206 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Three doors.]<br />

5 lb. maximum pressure to operate interior<br />

doors.<br />

Adjust door opening pressure /<br />

closing time unless accepted by<br />

DSA Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

2 $612.51<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

146-Signage: Rooms<br />

#205 and #206 on the<br />

2nd Floor at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

Mounting height is 60" from the finish floor to the<br />

centerline of the sign.<br />

Relocate existing signage. 3 $490.00<br />