University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

194. Single Accommodation Toilet - Unisex Restroom on the Left on the<br />

3rd Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

18” between centerline of water closet and side wall or partition. (18-1/2” (within dimensional tolerance).)<br />

42” min. clearance between centerline of water closet and opposite wall.<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet.<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high).<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (50”.)<br />

Front of toilet paper dispenser is within 36” of the back wall. (37”.)<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat. (Above grab bar.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />