University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

59. Visual and Audible Signals For Elevators - Southeast Side at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

Elevator has visual and audible signals indicating the position of the car on or between floors. The indication is positioned<br />

above the car control panel or over the door.<br />

The visual signal for each direction is a minimum of 2-1/2” x 2-1/2”, and visible from the proximity of the hall call<br />

button. NOTE: An automatic verbal announcement of the floor number at which a car stops or which a car passes may<br />

be substituted for the audible signal.<br />

Audible signal sounds are once for up and twice for down. (or equivalent)<br />

Audible signal is no less than 20 decibels with a frequency no higher than 1500 Hz.<br />

Centerline of the fixture is a minimum of 6’ (72”) in height above the lobby floor. NOTE: The use of in-car lanterns,<br />

located in or on the door jambs, visible from the proximity of the call buttons and conforming to items 1, 2, & 3 above<br />

shall or will be acceptable.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong>-59-1 (originally 1453-400)<br />