06.11.2014 Views

Pierce Annex

Pierce Annex

Pierce Annex

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Report #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong><br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

155-Seating, Tables and<br />

Work Surfaces: Room<br />

#206 on the 2nd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>. [Fume<br />

hood.]<br />

28" - 34" height of table or work surface that is<br />

36" wide.<br />

Replace the fume hood with an<br />

accessible fume hood<br />

workstation.<br />

3 $18,216.00 Until such time<br />

as accessible<br />

furniture /<br />

stations are<br />

available in this<br />

room staff shall<br />

be informed of<br />

the immediate<br />

availability of<br />

accessible<br />

furniture /<br />

stations that<br />

may be placed<br />

in the room to<br />

meet the needs<br />

of people with<br />

disabilities.<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

156-Protruding Objects:<br />

Room #206 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Fume hood.]<br />

Objects projecting from walls (i.e. telephones,<br />

etc.) have 4" maximum projection into walks,<br />

halls, corridors, passageways or aisles if lower<br />

edge of object is above 27" and below 80".<br />

Install cane detectable barrier<br />

below object.<br />

1 $245.01<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

157-Aisles: Room #206<br />

on the 2nd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

36" minimum width of aisles. Requires<br />

engineering/architectural<br />

evaluation.<br />

2 $7,115.62<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

158-Protruding Objects:<br />

Room #206 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Emergency eye wash.]<br />

Objects projecting from walls (i.e. telephones,<br />

etc.) have 4" maximum projection into walks,<br />

halls, corridors, passageways or aisles if lower<br />

edge of object is above 27" and below 80".<br />

Install cane detectable barrier<br />

below object.<br />

1 $122.51<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

160-Doors: Rooms #222<br />

and #219 on the 2nd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

[Two doors.]<br />

5 lb. maximum pressure to operate interior<br />

doors.<br />

Adjust door opening pressure /<br />

closing time unless accepted by<br />

DSA Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

2 $612.51<br />

6/1/2012 Page 19 of 32

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!