University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

204. Accessories - Unisex Restroom on the Right on the 3rd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

See Sequence #201 and #202 for additional recommendations.<br />

Areas noted in compliance:<br />

40” maximum height to bottom of reflective surface of mirror.<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Soap dispenser - 44-1/2” / paper towels - 45” / seat covers - 48” / toilet paper - 42-1/2”.)<br />

height above floor surface is recom-<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max.<br />

mended). (66-1/2”.)<br />

Recommendation:<br />

Install accessible coat hook.<br />

Relocate the paper towel dispenser / hand dryer.<br />

Relocate the soap dispenser.<br />

Photo #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong>-204-1 (originally 1680-400)<br />