06.11.2014 Views

Pierce Annex

Pierce Annex

Pierce Annex

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

134. Clear Space at Doors - Behind Room #204 on the 2nd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (3” to chair.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (0” to furniture.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong>-134-1 (originally 1573-400)<br />

216

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!