06.11.2014 Views

Pierce Annex

Pierce Annex

Pierce Annex

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

207. Water Fountains (Drinking) - Corridor on the 3rd Floor at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

32” minimum wide and 18” minimum deep alcove provided.<br />

18” minimum depth of fountain.<br />

27” high x 8” deep clear knee space under fountain.<br />

9” high x 17” deep toe clearance.<br />

Lever or push bar control is located 6” max. from front edge.<br />

Bubbler outlet is 6” maximum from front.<br />

Bubbler outlet is 36” maximum from floor.<br />

4” minimum height of stream.<br />

Two fountains are provided, one that is wheelchair accessible and one at normal height for those persons having difficulty<br />

bending or stooping.<br />

Areas not meeting new construction standards:<br />

Stream of bubbler is parallel to front edge. (On angle.)<br />

The force required to activate controls does not exceed 5lbf. (7 lbs.)<br />

Recommendation:<br />

Adjust angle of stream.<br />

Reduce force needed to operate fountain controls ( 5 lb. maximum).<br />