University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

57. Elevators - Southeast Side at <strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

Located near major path of travel and are accessible at all times the building is occupied.<br />

54” min. depth of the car platform (rear wall to door)<br />

51” min. clearance from the rear wall to return panel.<br />

36” min. clear width of doorway when fully open.<br />

Handrail is provided (1 minimum) on one wall of the car (rear preferred).<br />

Operation of doors (opening and closing) is automatic.<br />

Elevator is self leveling within 1/2” of floor landings.<br />

Emergency communication device does not require voice communication.<br />

The car inside allows for the turning of a wheelchair (enter the car, maneuver within reach of controls, and exit from the car).<br />

32” (+or- 1”) height of the handrail from the floor.<br />

Minimum of 1-1/2” clearance of the handrail from the wall.<br />

Handrail is smooth, no sharp edges.<br />

Doors are side-slide type (power-operated horizontally sliding).<br />

The clearance between the car platform sill and the edge of the hoistway landing is no greater than 1-1/4”.<br />

Doors remain fully open a minimum of 5 seconds when initially activated.<br />

Door jambs at all landings identify the floor by both raised Arabic numerals (minimum of 2” in height) and Braille<br />

symbols (immediately to left of numerals).<br />

Raised characters are on a contrasting background.<br />

Doorjamb markings are centered at 60” above the floor on both sides of the door.<br />

Emergency communication device is a maximum of 48” from the floor.<br />

The level of illumination at the platform, car threshold and landing sill is at least 5 foot-candles.<br />

Areas not meeting new construction standards:<br />

68” min. width of the car platform with off-center door panels. (65”.)<br />

Elevator doors have an automatic reopening device. The device opens the doors when objects pass through the opening<br />

at heights of 5” and 29” from the floor without requiring contact. Doors remain open for 20 seconds minimum. (5 seconds.)<br />

At grade level, a raised five-pointed star with an outside diameter of 2” is placed to the left of the raised character.<br />