Report #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong><br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

187-Doors: West<br />

Entrance to <strong>Pierce</strong><br />

<strong>Annex</strong> on the 3rd Floor.<br />

[One set of double<br />

doors.]<br />

189-Signage: West<br />

Entrance to <strong>Pierce</strong><br />

<strong>Annex</strong> on the 3rd Floor.<br />

190-Tactile Exit<br />

Signage: West Entrance<br />

to <strong>Pierce</strong> <strong>Annex</strong> on the<br />

3rd Floor.<br />

191-Doors: Unisex<br />

Restroom on the Left on<br />

the 3rd Floor at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

193-Identification<br />

Symbols, Restrooms:<br />

Unisex Restroom on the<br />

Left on the 3rd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

5 lb. maximum pressure to operate exterior<br />

doors. 3 seconds minimum for door closer to<br />

close from 70 degree position to within 3" of the<br />

latch [ADAAG 404.2.8.1 Door & gate closers<br />

require a 5 second minimum closing time from<br />

open position of 90 degree to 12 degree<br />

position].<br />

Permanent I.D. signs, when provided, are<br />

installed on the wall adjacent to the latch side of<br />

the door NOTE: At double leaf doors, and when<br />

there is no room on the latch side, signs shall be<br />

placed on the nearest adjacent wall, preferably<br />

on the right.<br />

Each exit door that leads directly to a gradelevel<br />

exterior exit by means of a stairway or<br />

ramp is identified by a tactile exit sign that states<br />

"EXIT STAIR DOWN", "EXIT RAMP DOWN",<br />

"EXIT STAIR UP", or "EXIT RAMP UP", as<br />

appropriate.<br />

5 lb. maximum pressure to operate interior<br />

doors. 3 seconds minimum for door closer to<br />

close from 70 degree position to within 3" of the<br />

latch [ADAAG 404.2.8.1 Door & gate closers<br />

require a 5 second minimum closing time from<br />

open position of 90 degree to 12 degree<br />

position].<br />

Unisex - 12" diameter circle 1/4" thick with 1/4"<br />

thick triangle superimposed in the circle. The<br />

circle and triangle symbols contrasts with the<br />

door, light on dark background or dark on light<br />

background [CBC 1115B.6 The triangle shall<br />

contrast w the circle and the circle shall contrast<br />

with the door]. Wall mounted signage: Symbol of<br />

accessibility is mounted on wall sign adjacent to<br />

latch side of door [ADAAG 703.6.1 & CBC<br />

1117B.5.5 Item 4 Pictograms shall have a field<br />

height of 6" ADAAG 703.6.1 Characters and<br />

Braille shall not be located in the pictogram<br />

field]. Verbal description as to restroom usage is<br />

placed directly below the pictogram, if utilized in<br />

conjunction with verbal identification and the<br />

border dimensions of this pictogram is a<br />

minimum of 6" in height.<br />

Adjust door opening pressure /<br />

closing time unless accepted by<br />

DSA Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

Install permanent ID sign to<br />

latch side of door.<br />

2 $306.26<br />

1 $183.75<br />

Provide compliant sign. 1 $183.75<br />

Adjust door opening pressure /<br />

closing time unless accepted by<br />

DSA Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

Install door-mounted sign on<br />

single door. Install wallmounted<br />

sign at single<br />

entrance.<br />

2 $306.26<br />

3 $367.51<br />

6/1/2012 Page 24 of 32