University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5508 <strong>Pierce</strong> <strong>Annex</strong> in Riverside, CA<br />

900 University Avenue<br />

1. Stairways - West Entrance to <strong>Pierce</strong> <strong>Annex</strong>.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All risers are closed.<br />

All steps have uniform riser height and tread width.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Ext. - Top landing and all steps have color striping minimum 2” wide and a maximum 4” wide parallel to, and not<br />

more than 1” maximum from tread nose or landing.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />