Report #UCR P5508 <strong>Pierce</strong> <strong>Annex</strong><br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

UCR P5508<br />

<strong>Pierce</strong><br />

<strong>Annex</strong><br />

244-Signage: Rooms<br />

#306 and #305 on the<br />

3rd Floor at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

246-Clear Space at<br />

Doors: Rooms #323,<br />

#324, #303 and #302 on<br />

the 3rd Floor at <strong>Pierce</strong><br />

<strong>Annex</strong>.<br />

247-Signage: Rooms<br />

#323, #324, #303 and<br />

#302 on the 3rd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

248-Doors: North<br />

Stairwell on the 3rd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

250-Signage: North<br />

Stairwell on the 3rd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

251-Tactile Exit<br />

Signage: North Stairwell<br />

on the 3rd Floor at<br />

<strong>Pierce</strong> <strong>Annex</strong>.<br />

252-Doors: North<br />

Entrance on the 3rd<br />

Floor at <strong>Pierce</strong> <strong>Annex</strong>.<br />

Mounting height is 60" from the finish floor to the<br />

centerline of the sign.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors, front<br />

approach.<br />

Mounting height is 60" from the finish floor to the<br />

centerline of the sign.<br />

32" minimum clear width of doorway. 5 lb.<br />

maximum pressure to operate interior doors.<br />

Permanent I.D. signs, when provided, are<br />

installed on the wall adjacent to the latch side of<br />

the door NOTE: At double leaf doors, and when<br />

there is no room on the latch side, signs shall be<br />

placed on the nearest adjacent wall, preferably<br />

on the right.<br />

Each exit door that leads directly to a gradelevel<br />

exterior exit by means of a stairway or<br />

ramp is identified by a tactile exit sign that states<br />

"EXIT STAIR DOWN", "EXIT RAMP DOWN",<br />

"EXIT STAIR UP", or "EXIT RAMP UP", as<br />

appropriate.<br />

5 lb. maximum pressure to operate exterior<br />

doors.<br />

Relocate existing signage. 3 $490.00<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1M $245.01<br />

Relocate existing signage. 3 $980.02<br />

Adjust door opening pressure /<br />

closing time unless accepted<br />

by DSA Fire / Life Safety.<br />

Consider issues connected<br />

with building pressure / climate<br />

control. Replace door and<br />

frame (concrete or block wall).<br />

Install permanent ID sign to<br />

latch side of door.<br />

2 $5,573.87<br />

1 $183.75<br />

Provide compliant sign. 1 $183.75<br />

Adjust door opening pressure /<br />

closing time unless accepted by<br />

DSA Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

2 $306.26<br />

6/1/2012 Page 31 of 32