BFX300I Offering ssssssss; Block out size nnnn; NTXID = nnnnnnnn.<br />
Severity: 2 (Diagnostic)<br />
Module: BFXCON in BFXTI.<br />
Explanation: The BFXTI transfer initiate program has issued a NETEX SOFFER to wait for the<br />
BFXTR program to connect to it. The name offered is “ssssssss” which will be the specified ID= of<br />
the user’s input parameters. The expected transfer is a receive operation; the incoming block size that<br />
the receiving BFX would like to used is nnnn.<br />
User Response: None<br />
BFX301I Offering ssssssss; Block in size nnnn, NTXID=nnnnnnnn.<br />
Severity: 2 (Diagnostic)<br />
Module: BFXCON in BFXTI, BFXJS.<br />
Explanation: The BFXJS job submitter or the BFXTI program has issued a NETEX SOFFER to wait<br />
for the corresponding program to connect to it. The name offered is “ssssssss” which will be the<br />
specified ID= of the user’s input parameters. The expected transfer is a receive operation; the incoming<br />
block size that the receiving BFX would like to used is nnnn.<br />
User Response: None<br />
BFX302I Connecting to ssssssss on host hhhhhhhh; Block in size nnnn; NTXID = nnnnnnnn.<br />
Severity: 2 (Diagnostic)<br />
Module: BFXCON in BFXTI, BFXTR.<br />
Explanation: When BFXTR is connecting back to it starting BFXTI, it has issued a NETEX<br />
SCONNECT to establish communications. “ssssssss” is the name to connect to as specified in the ID<br />
= or JID = user parameters; “hhhhhhhh” is the host name specified in the TO= or FROM= parameters.<br />
The direction of file transfer will cause this program to receive the file; the block size that is<br />
program is prepared to receive is nnnn.<br />
User Response: None<br />
BFX303I Connecting to ssssssss on host hhhhhhhh; Block out size nnnn; NTXID = nnnnnnnn.<br />
Severity: 2 (Diagnostic)<br />
Module: BFXCON in BFXTI, BFXTR.<br />
Explanation: When BFXTI is submitting a job to BFXJS, or when BFXTR is connecting back to its<br />
starting BFXTI, the BFX program has issued a NETEX SCONNECT to establish communications.<br />
“ssssssss” is the name to connect to as specified in the ID= or JID = user parameters; “hhhhhhhh” is<br />
the host name specified in the TO= or FROM= parameters. The direction of file transfer will cause<br />
this program to send a file; the block size that is program is prepared to send is nnnn.<br />
User Response: None<br />
BFX304I Connect complete.<br />
Severity: 0 (Diagnostic)<br />
Module: BFXCON in BFXTI, BFXTR.<br />
Explanation: A previously issued NETEX SCONNECT (see messages BFX302I and BFX303I) has<br />
successfully completed.<br />
User Response: None<br />
BFX305W Connect failed; ssssssss busy.<br />
Severity: 1 (Diagnostic)<br />
Module: BFXCON in BFXTI, BFXTR.<br />
Explanation: A previously issued NETEX SCONNECT (see messages BFX302I and BFX303I) did<br />
not succeed because the OFFER’ed application (hopefully BFXJS) was currently in use by some<br />
other network application. NETEX will retry the connection a number of times and at intervals determined<br />
during BFX generation.<br />
User Response: None<br />