BFXDEF#CLOSE<br />
Example:<br />
Default value:<br />
Allowed values:<br />
BFXDEF#BUSYMAX(180)<br />
NO<br />
NO YES<br />
This optional parameter specifies whether SCLOSE should be used to terminate the file transfer<br />
or not (instead of SDISC). IF SCLOSE is used, any other BFX components to be communicated<br />
with (BFXTI, BFXTR, BFXJS) must also use SCLOSE. It is recommended to use<br />
SCLOSE if all BFXs support it.<br />
Example:<br />
BFXDEF#CLOSE(YES)<br />
BFXDEF#CONTRY<br />
Default value: 5<br />
Allowed values: 1-3600<br />
This optional parameter (abbreviated CON) specifies the time interval (in seconds) between<br />
CONNECT attempts by BFXTI or BFXTR if the offering side is reported “busy” or "not present”<br />
by the remote NETEX. This parameter is also used as the time interval between<br />
OFFER attempts by BFXTI or BFXJS if MAX SESSIONS EXCEEDED. If omitted, the default<br />
is 5 seconds.<br />
Example:<br />
BFXDEF#CONTRY(60)<br />
BFXDEF#CTLDD<br />
Default value: SYSIN<br />
Allowed values: any valid DD name, up to 8 characters in length<br />
This parameter specifies the DDNAME of the file to be used for the input file containing the<br />
BFX control statements. The default is CLTDD = SYSIN.<br />
Example:<br />
BFXDEF#CTLDD(STDIN)<br />
BFXDEF#DISCMAX<br />
Default value: 30<br />
Allowed values: 1-3600<br />
This optional parameter (abbreviated DIS) specifies the maximum actual time (in seconds)<br />
that the BFXTI or BFXTR program will wait for the offering program to be offered on the<br />
remote computer. The connecting program will retry every CONTRY seconds and will receive<br />
a not present indication a maximum of DISCMAX/CONTRY times before informing<br />
the user that the connection attempt is not possible. If omitted, the default is 30 seconds.<br />
BFXDEF#HOST<br />
Example:<br />
Default value:<br />
Allowed values:<br />
BFXDEF#DISCMAX(60)<br />
‘’ (none)<br />
any name, up to 8 characters in length<br />
This parameter specifies a default TO or FROM host address to be used if this parameter is<br />
omitted by the BFX user. This parameter is particularly useful in the environment where<br />
nearly all file transfers are between two processors. The BFXDEF macro does not supply a<br />
MAN-REF-H211-05 Installing BFX Page 39