BFXJSD#JBLOCK<br />

BFXJSD#JBMOD<br />

Default value: 800<br />

Allowed values:<br />

up to 65535 (64K)<br />

This parameter specifies the default block size to be used to move the job file over the<br />

<strong>NetEx</strong>/IP network. This value will be adjusted upwards by the BFX default record module if<br />

it is insufficient to contain a logical record in the file. The default is 800 bytes.<br />

Example:<br />

Default value:<br />

Allowed values:<br />

BFXJSD#JBLOCK(8192)<br />

STANDARD<br />

any name, up to 8 characters in length<br />

This parameter specifies the alphabetic name of the default block module to be used for submitting<br />

the job. The default is JBMOD=STANDARD, which is a symbolic name that calls<br />

the RBM or SBM BFX default block modules through the MDT table.<br />

Example:<br />

BFXJSD#JBMOD(STD1)<br />

BFXJSD#JBPARM<br />

Default value: ‘’ (none)<br />

Allowed values: any character string, up to 64 bytes in length<br />

This parameter specifies a default string of character parameters to be passed to the invoked<br />

block module. This string, if provided, may be up to 64 characters in length. By default, a<br />

string of all blanks is passed to the block module. The standard BFX block modules ignore<br />

the JBPARM parameter.<br />

Example:<br />

BFXJSD#JBPARM(‘ABCD EFGHIJKLMNOP’)<br />

BFXJSD#JID<br />

Default value: BFXJS<br />

Allowed values: any name, up to 8 characters in length<br />

This parameter specifies the name that BFXJS is to provide to NETEX to OFFER its job<br />

submission services. If omitted, the default is JID=BFXJS.<br />

Example:<br />

BFXJSD#JID(BXJST)<br />

BFXJSD#JRMOD<br />

Default value: STANDARD<br />

Allowed values: any character string, up to 8 bytes in length<br />

This parameter specifies the alphabetic name of the default record module to be used for<br />

submitting the job. If used in a JES3 environment, specify JRMOD=JES3JS. The default is<br />

JRMOD=STANDARD, which is a symbolic name that calls the RRM or SRM BFX default<br />

record modules through the MDT table.<br />

Example:<br />

BFXJSD#JRMOD(STD1)<br />

Page 46 Installing BFX MAN-REF-H211-05