BUFLEN BUFLEV MSGLEN MSGLEV<br />
Significance<br />
0 -1 0 0 Receiving module is being called for the first time.<br />
> = 0 0-14 0 0 Normal data transfer. Data should be processed. Nonending<br />
delimiter should be processed. If BUFLEN=0,<br />
then a zero length record is being provided.<br />
0 15 0 0 Normal EOI. The receiving module should close the file<br />
and return with an optional message. Last time receiving<br />
module is called.<br />
> 0 16 0 0 File transfer aborted. Receiving module should close the<br />
file and return with an optional message. Last time receiving<br />
module-is called.<br />
Table 3. Block module exit parameters<br />
BUFLEN BUFLEV MSGLEN MSGLEV Significance<br />
-- 0-15 0 0-15 Normal return from data accept.<br />
-- 0-15 > 0 0-15 Normal return from accept with message provided. Message<br />
will be printed locally and sent back to the sender.<br />
-- 16 0 0-15 Abort transfer. A default message will be generated,<br />
printed locally, sent as an abort message to the sending<br />
BFX. The module will not be called again.<br />
-- 16 >0 0-15 Abort transfer. The provided message will be printed locally<br />
and sent as an abort message to the sending BFX.<br />
The module will not be called again.<br />
Table 4. Block module exit parameters<br />
MAN-REF-H211-05 Appendix A: User Modules Page 65