BUFLEN BUFLEV MSGLEN MSGLEV<br />

Significance<br />

0 -1 0 0 Receiving module is being called for the first time.<br />

> = 0 0-14 0 0 Normal data transfer. Data should be processed. Nonending<br />

delimiter should be processed. If BUFLEN=0,<br />

then a zero length record is being provided.<br />

0 15 0 0 Normal EOI. The receiving module should close the file<br />

and return with an optional message. Last time receiving<br />

module is called.<br />

> 0 16 0 0 File transfer aborted. Receiving module should close the<br />

file and return with an optional message. Last time receiving<br />

module-is called.<br />

Table 3. Block module exit parameters<br />

BUFLEN BUFLEV MSGLEN MSGLEV Significance<br />

-- 0-15 0 0-15 Normal return from data accept.<br />

-- 0-15 > 0 0-15 Normal return from accept with message provided. Message<br />

will be printed locally and sent back to the sender.<br />

-- 16 0 0-15 Abort transfer. A default message will be generated,<br />

printed locally, sent as an abort message to the sending<br />

BFX. The module will not be called again.<br />

-- 16 >0 0-15 Abort transfer. The provided message will be printed locally<br />

and sent as an abort message to the sending BFX.<br />

The module will not be called again.<br />

Table 4. Block module exit parameters<br />