BFX317W Offer failed; maximum sessions exceeded.<br />

Severity: 1 (Diagnostic)<br />

Module: BFXCON in BFXTI, BFXJS.<br />

Explanation: A previously issued NETEX SOFFER (see messages BFX300I and BFX301I) failed<br />

because the NETEX maximum sessions limit had already been reached. NETEX will retry the<br />

OFFER a number of times at intervals determined during BFX generation or at run time.<br />

User Response: None<br />

BFX318W Connect failed; maximum sessions exceeded.<br />

Severity: 1 (Diagnostic)<br />

Module: BFXCON in BFXTI, BFXTR.<br />

Explanation: A previously issued NETEX SCONNECT (see messages BFX302I and BFX303I)<br />

failed because the NETEX maximum sessions limit had already been reached. NETEX will retry the<br />

CONNECT a number of times at intervals determined during BFX generation or at run time.<br />

User Response: None.<br />

BFX350I General Purpose Msg for Use by user written record modules.<br />

Severity: 8 (Informative)<br />

Module: ?<br />

Explanation: User Defined 80 Character Msg area.<br />

User Response: Indeterminate.<br />

Page 108 Appendix C: BFX Error Messages MAN-REF-H211-05