<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-RD-09-0028<br />

page 108 of 204<br />

S2-<strong>PDGS</strong>-DC-040<br />

The <strong>PDGS</strong>/DC function shall be able to retrieve autonomously data from all input<br />

electronic interfaces according to a well-defined configuration.<br />

S2-<strong>PDGS</strong>-DC-045<br />

The <strong>PDGS</strong>/DC function shall be able to deliver autonomously data to all output electronic<br />

interfaces according to a well-defined configuration.<br />

S2-<strong>PDGS</strong>-DC-050<br />

The <strong>PDGS</strong>/DC shall operate autonomously in a data-driven manner based on the<br />

detection of new data made available by other systems at the configured interface for<br />

circulation to another system's interface.<br />

S2-<strong>PDGS</strong>-DC-055<br />

The <strong>PDGS</strong>/DC function shall allow the operator to interactively add / modify / delete the<br />

configuration of electronic input or output interfaces within or external to the <strong>PDGS</strong> via a<br />

HMI.<br />

S2-<strong>PDGS</strong>-DC-060<br />

The <strong>PDGS</strong>/DC function shall allow associating access methods, protocols, polling<br />

frequencies, etc to each electronic interface by configuration.<br />

S2-<strong>PDGS</strong>-DC-065<br />

The <strong>PDGS</strong>/DC function shall allow the operator to interactively add / modify / delete the<br />

configuration of circulation rules between electronic input and output interfaces via an<br />

HMI.<br />

S2-<strong>PDGS</strong>-DC-070<br />

The <strong>PDGS</strong>/DC function shall be able by configuration to prevent the circulation of the<br />

same data twice between the same interfaces. Accordingly the DC function shall keep<br />

track of all the circulation operations performed.<br />

S2-<strong>PDGS</strong>-DC-075<br />

The <strong>PDGS</strong>/DC function shall process autonomously the data from/to media interfaces<br />

limiting operator intervention to the sole initial media preparation (e.g. tape loading, disk<br />

connection, etc), media disposal (unloading, disconnection, etc) and shipment activities.<br />

S2-<strong>PDGS</strong>-DC-080<br />

The <strong>PDGS</strong>/DC function shall be able to perform several media interface circulation<br />

operations on different media in parallel.<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!