<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-RD-09-0028<br />

page 129 of 204<br />

S2-<strong>PDGS</strong>-DAG-205<br />

It shall be possible to deploy and operate the <strong>PDGS</strong>/DAG function in a collaborative<br />

CDAM centre acting as local download server.<br />

S2-<strong>PDGS</strong>-DAG-210<br />

The <strong>PDGS</strong>/DAG management function shall be deployed and operated locally in the<br />

PDMC acting as central physical point of access supported by at least on PAC instance<br />

configured as hot-redundant backup for this function.<br />

S2-<strong>PDGS</strong>-DAG-215<br />

The <strong>PDGS</strong>/DAG function shall supply status information over all its local processes and<br />

resources (i.e. log information, disk volumes usage, alarms, etc.) in real-time via the<br />

collocated M&C function.<br />

S2-<strong>PDGS</strong>-DAG-220<br />

The <strong>PDGS</strong>/DAG function shall operate autonomously and mechanically as triggered by<br />

download requests and hosted-processing requests.<br />

S2-<strong>PDGS</strong>-DAG-225<br />

The <strong>PDGS</strong>/DAG function shall systematically notify the MMUS function of the<br />

successful/unsuccessful completion of a product download request.<br />

S2-<strong>PDGS</strong>-DAG-230<br />

The <strong>PDGS</strong>/DAG function shall systematically provide a summary report to the MMUS<br />

function on completion of every download including the volumes of data downloaded, the<br />

time to serve the request, etc, or qualifying the source of the problem in a human<br />

understandable message for failed downloads.<br />

5.13.4 RAMS REQUIREMENTS<br />

S2-<strong>PDGS</strong>-DAG-235<br />

The <strong>PDGS</strong>/DAG function shall ensure nominal operations in hot-redundant configuration<br />

unattended for better than 99.7% of the time computed over one month time window and<br />

assuming a degradation of such figure for no more than one day.<br />

S2-<strong>PDGS</strong>-DAG-240<br />

The <strong>PDGS</strong>/DAG function shall ensure that the User-Products delivered are consistent and<br />

complete of all data.<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!