GSC Sentinel-2 PDGS SRD - emits - ESA
GSC Sentinel-2 PDGS SRD - emits - ESA
GSC Sentinel-2 PDGS SRD - emits - ESA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />
Issue 1 Revision 2 (draft) - 25.07.2010<br />
GMES-GSEG-EOPG-RD-09-0028<br />
page 51 of 204<br />
S2-<strong>PDGS</strong>-SYS-420<br />
The <strong>PDGS</strong> CGS shall support continuous downlinks via X-Band of up to 13 minutes.<br />
S2-<strong>PDGS</strong>-SYS-425<br />
The <strong>PDGS</strong> shall support an overall downlink flow of 20 minutes per orbit in average per<br />
satellite.<br />
S2-<strong>PDGS</strong>-SYS-430<br />
The <strong>PDGS</strong> shall be sized to support:<br />
initially, only <strong>Sentinel</strong>-2A in preparation, commissioning and operation<br />
subsequently, with <strong>Sentinel</strong>-2A in operation, <strong>Sentinel</strong>-2B in preparation, commissioning<br />
and operation<br />
S2-<strong>PDGS</strong>-SYS-435<br />
The MPAC shall be sized for processing and archiving such as to support the dataprocessing<br />
operations required nominally for IPF verification activities and anomaly<br />
investigation activities.<br />
S2-<strong>PDGS</strong>-SYS-440<br />
The <strong>PDGS</strong> network communications to the FOS shall support the transfer of up 20MBytes<br />
of HKTM data per orbit.<br />
5.1.4 OPERATIONAL REQUIREMENTS<br />
S2-<strong>PDGS</strong>-SYS-445<br />
All the <strong>PDGS</strong> HMIs shall be provided with the following characteristics as a minimum:<br />
Ability to monitor on-going activities by progress bars or equivalent indicators able to<br />
provide elapsed & estimated completion times<br />
Ability to stop/cancel/pause/resume an on-going activity<br />
Preliminary syntax checks for data insertions<br />
Confirmation for critical commands submission (e.g. deletion)<br />
Multiple window display<br />
Random movement through fields<br />
Context-sensitive menus<br />
Context-sensitive help.<br />
S2-<strong>PDGS</strong>-SYS-450<br />
The <strong>PDGS</strong> HMIs shall ensure that a feedback is systematically provided to the<br />
user/operator/administrator after initiating a transaction as a minimum indicating that a<br />
process has been initiated.<br />
<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />
© <strong>ESA</strong><br />
The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />
communicated to any third party without written permission from <strong>ESA</strong>.