S2-<strong>PDGS</strong>-DC-130<br />

The <strong>PDGS</strong>/DC function shall be able to support an overall average sustained circulation<br />

throughput via media of 200 Mbps.<br />

5.9.3 OPERATIONAL REQUIREMENTS<br />

S2-<strong>PDGS</strong>-DC-135<br />

The <strong>PDGS</strong>/DC function shall be deployed and operated locally in all <strong>PDGS</strong> centres.<br />

S2-<strong>PDGS</strong>-DC-140<br />

It shall be possible to deploy the <strong>PDGS</strong>/DC function in a collaborative CDAM centre for<br />

autonomous operations by a third-party.<br />

S2-<strong>PDGS</strong>-DC-145<br />

The <strong>PDGS</strong>/DC function shall generate synthetic operation reports along time, providing<br />

periodic and self-consistent updates over the recently performed activities (successful and<br />

failed) including a detailed inventory of all data circulations performed. The generated<br />

reports shall be systematically routed to the MCC function for configuration control and<br />

further processing.<br />

S2-<strong>PDGS</strong>-DC-150<br />

The <strong>PDGS</strong>/DC function shall supply status information over all its processes and<br />

resources (i.e. log information, disk volumes usage, alarms, etc.) in real-time via the M&C<br />

function.<br />

S2-<strong>PDGS</strong>-DC-155<br />

The <strong>PDGS</strong>/DC function shall minimize human intervention when performing retrieval /<br />

delivery operations from / to media interfaces.<br />

S2-<strong>PDGS</strong>-DC-160<br />

The <strong>PDGS</strong>/DC function shall alert the operator by making use of the M&C function<br />

capabilities for all operations requiring urgent manual intervention including:<br />

Media loading/disposal operations;<br />

Contingency operations on repeated failures of circulation operations from/to media or<br />

electronic interfaces.<br />

S2-<strong>PDGS</strong>-DC-165<br />

The <strong>PDGS</strong>/DC function shall centralise all data exchanges (file-based, e-mail, productdata,<br />

etc) for data input and output via electronic or media interfaces between every<br />

<strong>PDGS</strong> centre and its remote interfaces unless, specified otherwise.<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!