<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />
<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />
Issue 1 Revision 2 (draft) - 25.07.2010<br />
GMES-GSEG-EOPG-RD-09-0028<br />
page 171 of 204<br />
S2-<strong>PDGS</strong>-MPA-255<br />
The <strong>PDGS</strong>/MPA function shall support the expert teams on the specific QC analysis<br />
activities and as such providing the necessary image visualisation, manipulation and<br />
transformation tools.<br />
S2-<strong>PDGS</strong>-MPA-260<br />
The <strong>PDGS</strong>/MPA function shall mechanically perform End-to-End System Performance<br />
monitoring activities daily to guarantee the timely identification of any anomaly in the<br />
<strong>PDGS</strong> functioning, performance or configuration.<br />
S2-<strong>PDGS</strong>-MPA-265<br />
The <strong>PDGS</strong>/MPA function shall accept investigation requests from the POM, carry out the<br />
investigation, and systematically return back an investigation report in response.<br />
S2-<strong>PDGS</strong>-MPA-270<br />
The <strong>PDGS</strong>/MPA function shall accept updates of the mission quality targets from the POM<br />
and adapt the QC and Cal/Val operations accordingly.<br />
S2-<strong>PDGS</strong>-MPA-275<br />
The <strong>PDGS</strong>/MPA function shall provide quality-reports to the POM regularly.<br />
(recurrent quality control reports include: (1) Daily cyclic quality reports, (2) N-day cyclic<br />
reports)<br />
S2-<strong>PDGS</strong>-MPA-280<br />
The <strong>PDGS</strong>/MPA function shall provide quality-reports to the CDS/SCI regularly via the<br />
MCC function in electronic format according to the applicable CDS/SCI interface.<br />
(recurrent quality control reports include: (1) Daily cyclic quality reports, (2) N-day cyclic<br />
reports)<br />
S2-<strong>PDGS</strong>-MPA-285<br />
The <strong>PDGS</strong>/MPA function shall regularly provide quality-reports to the <strong>PDGS</strong> first-line<br />
Support-Desk operated by the MMUS function for on-line publishing to the users.<br />
Recurrent quality control reports include: (1) Daily cyclic quality reports, (2) N-day cyclic<br />
reports, (3) specific announcements.<br />
S2-<strong>PDGS</strong>-MPA-290<br />
The <strong>PDGS</strong>/MPA function shall accept anomaly investigation requests from the MMUS<br />
function or the CDS/SCI Support-Desks, performing the verification activities and<br />
systematically return back an investigation report for each accepted request.<br />
S2-<strong>PDGS</strong>-MPA-295<br />
The <strong>PDGS</strong>/MPA function shall accept processor verification requests from the RP<br />
function, perform the verification activities and systematically return a processor<br />
© <strong>ESA</strong><br />
The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />
communicated to any third party without written permission from <strong>ESA</strong>.