<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />
Issue 1 Revision 2 (draft) - 25.07.2010<br />
GMES-GSEG-EOPG-RD-09-0028<br />
page 173 of 204<br />
configuration coherency used during the MSI sensing and product generation activities<br />
and alert on any miss-alignment.<br />
S2-<strong>PDGS</strong>-MPA-340<br />
The <strong>PDGS</strong>/MPA function shall monitor the <strong>PDGS</strong> archive completeness and performance.<br />
Accordingly it shall compare the generated production wrt the archived production and<br />
detect potential inconsistencies.<br />
S2-<strong>PDGS</strong>-MPA-345<br />
The <strong>PDGS</strong>/MPA function shall monitor the production availability and accessibility to the<br />
users. Accordingly it shall compare the archived production wrt the available production<br />
offered to the users through the CDS/DAIL and MMUS function.<br />
S2-<strong>PDGS</strong>-MPA-350<br />
The <strong>PDGS</strong>/MPA function shall monitor the production availability and accessibility<br />
timeliness wrt the sensing time and the downlink mode (nominal, NRT and RT).<br />
Accordingly it shall check whether the production was available according to the<br />
timeliness required.<br />
S2-<strong>PDGS</strong>-MPA-355<br />
The <strong>PDGS</strong>/MPA function shall monitor the MSI SWIR detectors performance wrt expected<br />
accuracy and established quality thresholds for the generated production. Such monitoring<br />
shall allow the expert teams to understand the need to activate the MSI decontamination.<br />
S2-<strong>PDGS</strong>-MPA-360<br />
The <strong>PDGS</strong>/MPA function shall identify the MSI data acquired simultaneously to OCP<br />
operations and accordingly assess the quality of the generated production. The MPA shall<br />
support the potential qualification of MSI and OCP simultaneous operations by the<br />
assessment of the micro vibrations effects on the geometric accuracy.<br />
S2-<strong>PDGS</strong>-MPA-365<br />
The <strong>PDGS</strong>/MPA function shall recognize and identify the images acquired during eclipse<br />
to avoid unnecessary alerts on the generated production.<br />
5.18.4 RAMS REQUIREMENTS<br />
S2-<strong>PDGS</strong>-MPA-370<br />
The <strong>PDGS</strong>/MPA function shall ensure the coherency and integrity of all the payload<br />
configuration parameters generated and delivered as result of the performed QC and<br />
calibration activities.<br />