page 173 of 204<br />

configuration coherency used during the MSI sensing and product generation activities<br />

and alert on any miss-alignment.<br />

S2-<strong>PDGS</strong>-MPA-340<br />

The <strong>PDGS</strong>/MPA function shall monitor the <strong>PDGS</strong> archive completeness and performance.<br />

Accordingly it shall compare the generated production wrt the archived production and<br />

detect potential inconsistencies.<br />

S2-<strong>PDGS</strong>-MPA-345<br />

The <strong>PDGS</strong>/MPA function shall monitor the production availability and accessibility to the<br />

users. Accordingly it shall compare the archived production wrt the available production<br />

offered to the users through the CDS/DAIL and MMUS function.<br />

S2-<strong>PDGS</strong>-MPA-350<br />

The <strong>PDGS</strong>/MPA function shall monitor the production availability and accessibility<br />

timeliness wrt the sensing time and the downlink mode (nominal, NRT and RT).<br />

Accordingly it shall check whether the production was available according to the<br />

timeliness required.<br />

S2-<strong>PDGS</strong>-MPA-355<br />

The <strong>PDGS</strong>/MPA function shall monitor the MSI SWIR detectors performance wrt expected<br />

accuracy and established quality thresholds for the generated production. Such monitoring<br />

shall allow the expert teams to understand the need to activate the MSI decontamination.<br />

S2-<strong>PDGS</strong>-MPA-360<br />

The <strong>PDGS</strong>/MPA function shall identify the MSI data acquired simultaneously to OCP<br />

operations and accordingly assess the quality of the generated production. The MPA shall<br />

support the potential qualification of MSI and OCP simultaneous operations by the<br />

assessment of the micro vibrations effects on the geometric accuracy.<br />

S2-<strong>PDGS</strong>-MPA-365<br />

The <strong>PDGS</strong>/MPA function shall recognize and identify the images acquired during eclipse<br />

to avoid unnecessary alerts on the generated production.<br />

5.18.4 RAMS REQUIREMENTS<br />

S2-<strong>PDGS</strong>-MPA-370<br />

The <strong>PDGS</strong>/MPA function shall ensure the coherency and integrity of all the payload<br />

configuration parameters generated and delivered as result of the performed QC and<br />

calibration activities.<br />

<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!