<strong>ESA</strong> UNCLASSIFIED – For Official Use<br />

<strong>GSC</strong> <strong>Sentinel</strong>-2 <strong>PDGS</strong> <strong>SRD</strong><br />

Issue 1 Revision 2 (draft) - 25.07.2010<br />

GMES-GSEG-EOPG-RD-09-0028<br />

page 166 of 204<br />

S2-<strong>PDGS</strong>-MPA-050<br />

The <strong>PDGS</strong>/MPA function shall be able to provide comprehensible quality reports on the<br />

outcome of all Cal/Val, Off-line QC and End-to-End System Performance activities.<br />

S2-<strong>PDGS</strong>-MPA-055<br />

The <strong>PDGS</strong>/MPA function activities and reporting shall be focussed towards minimising the<br />

time to investigate and recover from anomalies.<br />

S2-<strong>PDGS</strong>-MPA-060<br />

The <strong>PDGS</strong>/MPA function shall be able to generate status reports that summarize the<br />

overall performance of the <strong>PDGS</strong> System and every individual function covering a user<br />

defined time-window and generated with regular frequencies (i.e. daily, N-day cyclic) and<br />

by on-demand triggering.<br />

S2-<strong>PDGS</strong>-MPA-065<br />

Whenever possible, the <strong>PDGS</strong>/MPA function shall include in the quality-reports a<br />

proposed solution for correcting anomalies identified (e.g. trigger Cal/Val activities to<br />

update on-ground configuration parameters or to perform the verification of a new IPF<br />

version).<br />

S2-<strong>PDGS</strong>-MPA-070<br />

The generated reports shall present a consistent and coherent structure providing a<br />

harmonised look & feel to ease the reading and comprehension. In addition, according to<br />

configuration, they shall be generated in the respective format(s) adequate for the on-line<br />

publishing, distribution and local visualisation and printing (e.g. on-line HTML page,<br />

downloadable PDF, etc).<br />

S2-<strong>PDGS</strong>-MPA-075<br />

The <strong>PDGS</strong>/MPA function shall be able log all the automated activities (i.e. activities<br />

performed without the presence of the operator) via the <strong>PDGS</strong>/M&C function).<br />

S2-<strong>PDGS</strong>-MPA-080<br />

The <strong>PDGS</strong>/MPA function shall be able to generate quality-reports with contents and<br />

format compliant with the applicable CDS/SCI interface, providing comprehensive<br />

information on the overall quality of the <strong>Sentinel</strong>-2 products and Data-Sets.<br />

S2-<strong>PDGS</strong>-MPA-085<br />

The <strong>PDGS</strong>/MPA function shall be able to generate a processor verification report and/or<br />

anomaly reports in output of all IDP function verification activities.<br />

S2-<strong>PDGS</strong>-MPA-090<br />

The <strong>PDGS</strong>/MPA function shall implement clear interfaces with human operators for all notautomatic<br />

tasks.<br />

© <strong>ESA</strong><br />

The copyright of this document is the property of <strong>ESA</strong>. It is supplied in confidence and shall not be reproduced, copied or<br />

communicated to any third party without written permission from <strong>ESA</strong>.