C–VirtualNIC Interface Configuration and Administration<br />

VirtualNIC Interface Configuration and Administration<br />

NOTE:<br />

An EVIC has 2 IOCs; one for each Ethernet port. Each EVIC contains a<br />

unique set of IOCGUIDs: (e.g., IOC 1 maps to Ethernet Port 1 and IOC 2<br />

maps to Ethernet Port 2).<br />

1. Ensure you are logged in as a root user.<br />

2. Type ib_qlgc_vnic_query<br />

This displays detailed information about all the EVIC/VEx IOCs present on<br />

the fabric. For example:<br />

# ib_qlgc_vnic_query<br />

HCA No = 0, HCA = mlx4_0, Port = 1, Port GUID = 0x0002c903000010f9,<br />

State = Active<br />

IO Unit Info:<br />

port LID: 0009<br />

port GID: fe8000000000000000066a11de000070<br />

change ID: 0003<br />

max controllers: 0x02<br />

controller[ 1]<br />

GUID: 00066a01de000070<br />

vendor ID: 00066a<br />

device ID: 000030<br />

IO class : 2000<br />

ID: EVIC in Chassis 0x00066a00db00001e, Slot 1, Ioc 1<br />

service entries: 2<br />

service[ 0]: 1000066a00000001 /<br />

InfiniNIC.InfiniConSys.Control:01<br />

service[ 1]: 1000066a00000101 /<br />

InfiniNIC.InfiniConSys.Data:01<br />

IO Unit Info:<br />

port LID: 000b<br />

port GID: fe8000000000000000066a21de000070<br />

change ID: 0003<br />

max controllers: 0x02<br />

C-2 D000046-005 B