G–ULP Troubleshooting<br />

Troubleshooting VirtualNIC and VIO Hardware Issues<br />

Verify that the proper VirtualNIC driver is running<br />

Check that a VirtualNIC driver is running by issuing an lsmod command on the<br />

InfiniBand host. Make sure that the qlgc_vnic is displayed on the list of<br />

modules. Following is an example:<br />

st186:~ # lsmod<br />

Module<br />

Size Used by<br />

cpufreq_ondemand 25232 1<br />

cpufreq_userspace 23552 0<br />

cpufreq_powersave 18432 0<br />

powernow_k8 30720 2<br />

freq_table<br />

22400 1 powernow_k8<br />

qlgc_srp 93876 0<br />

qlgc_vnic 116300 0#<br />

Verifying that the qlgc_vnic.cfg file contains the correct<br />

information<br />

Use the following scenarios to verify that the qlgc_vnic.cfg file contains a<br />

definition for the applicable virtual interface:<br />

Issue the command ib_qlgc_vnic_query to get the list of IOCs the host<br />

can see.<br />

If the list is empty, there may be a syntax error in the qlgc_vnic.cfg file (e.g., a<br />

missing semicolon). Look in /var/log/messages at the time qlgc_vnic was<br />

last started to see if any error messages were put in the log at that time.<br />

If the qlgc_vnic.cfg file has been edited since the last time the VirtualNIC<br />

driver was started, the driver needs restarted. To restart the driver, so that it uses<br />

the current qlgc_vnic.cfg file, issue a /etc/init.d/qlgc_vnic restart.<br />

G-2 D000046-005 B