D–SRP Configuration<br />

<strong>QLogic</strong> SRP Configuration<br />

2 Adapter Ports and 2 Ports on a Single VIO Module<br />

In this example, traffic is load balanced between adapter Port 2/VIO hardware<br />

Port 1 and adapter Port1/VIO hardware Port 1. If one of the sessions goes down<br />

(due to an InfiniBand cable failure or an FC cable failure), all traffic will begin using<br />

the other session.<br />

session<br />

begin<br />

card: 0<br />

port: 2<br />

targetIOCProfileIdString: "FVIC in Chassis<br />

0x00066A0050000123, Slot 1, IOC 1"<br />

initiatorExtension: 3<br />

end<br />

session<br />

begin<br />

card: 0<br />

port: 1<br />

targetIOCProfileIdString: "FVIC in Chassis<br />

0x00066A0050000123, Slot 1, IOC 2"<br />

initiatorExtension: 3<br />

end<br />

adapter<br />

begin<br />

description: "Test Device"<br />

roundrobinmode: 1<br />

end<br />